
* Please be kindly noted products are not for therapeutic use. We do not sell to patients.
Product Introduction
ATTO 655-Biotin is a fluorescent dye that incorporates a biotin moiety, facilitating its use in avidin-biotin complex applications. This compound features a conjugated aromatic system, characteristic of the ATTO dye series, which supports efficient excitation and emission properties in the far-red spectrum. ATTO 655-Biotin is commonly employed in fluorescence microscopy and flow cytometry for labeling biomolecules where high photostability and distinct spectral separation are required.
Chemical Information
Product Specification
Application
Chemical Information
| Purity | ≥95.0% (HPCE) |
| NACRES | NA.32 |
Product Specification
| Excitation | 655 |
| Emission | 680 |
| Properties Quality Level | 100 |
| Storage | −20 °C |
Application
ATTO 655-Biotin is a biotinylated ATTO 655 fluorophore designed for fluorescent labeling in affinity-based workflows. The ATTO 655 dye provides red spectral emission for sensitive visualization, while the biotin handle enables strong, widely used capture by streptavidin or avidin conjugates. This combination supports robust construction of fluorescent affinity reagents, imaging probes, and assay components where standardized biotin-streptavidin coupling is advantageous.
1. Streptavidin Affinity Labeling
ATTO 655-Biotin is used to generate fluorescent streptavidin/avidin conjugates for labeling biomolecules, affinity reagents, and assay surfaces. Researchers commonly employ it to decorate streptavidin-coated beads, plates, or membranes for fluorescence readouts in binding experiments, washing-based workflows, and platform development. The biotin moiety facilitates straightforward incorporation into streptavidin-based systems, while the ATTO 655 dye enables red-channel imaging and quantification on common fluorescence instrumentation.
2. Fluorescence Microscopy Tracing
ATTO 655-Biotin supports fluorescence microscopy studies that rely on biotin-streptavidin localization strategies, including visualization of labeled proteins, receptor-associated complexes, and biomolecular assemblies on prepared substrates. In cellular and biomaterials imaging workflows, it is frequently used as a fluorescent affinity tag to track binding events after incubation with streptavidin-functionalized targets. The red-emitting ATTO 655 dye is particularly useful when multiplexing with other fluorophores or when minimizing interference from shorter-wavelength channels.
3. Flow Cytometry Staining
ATTO 655-Biotin is applied in flow cytometry workflows that use biotin-streptavidin coupling to introduce a defined fluorescent signal onto cell-associated or bead-associated targets. Typical use cases include labeling biotinylated antibodies, affinity ligands, or engineered binding reagents followed by streptavidin-ATTO 655 complex formation for red fluorescence detection. This approach is valued in assay development because it leverages standardized biotin chemistry to control labeling stoichiometry and to integrate readily with existing streptavidin-based staining schemes.
4. Diagnostic Reagent Development
ATTO 655-Biotin is frequently incorporated into fluorescence-based diagnostic reagent prototypes and research assay kits where biotinylated components need to be converted into trackable fluorescent reagents. Developers use it to build fluorescent affinity conjugates for nucleic-acid or protein assay formats that rely on streptavidin capture, including lateral-flow style research constructs and bead-based binding assays. The biotin functionality supports modular reagent design, while the ATTO 655 emission supports quantitation in red fluorescence channels for assay readout.
Recommended Services
Recommended Articles
- Hoechst Dyes: Definition, Structure, Mechanism and Applications
- Mastering the Spectrum: A Comprehensive Guide to Cy3 and Cy5 Dyes
- Fluorescent Probes: Definition, Structure, Types and Application
- Fluorescent Dyes: Definition, Mechanism, Types and Application
- Coumarin Dyes: Definition, Structure, Benefits, Synthesis and Uses
- Unlocking the Power of Fluorescence Imaging: A Comprehensive Guide
- Cell Imaging: Definitions, Systems, Protocols, Dyes, and Applications
- Lipid Staining: Definition, Principles, Methods, Dyes, and Uses
- Flow Cytometry: Definition, Principles, Protocols, Dyes, and Uses
- Nucleic Acid Staining: Definition, Principles, Dyes, Procedures, and Uses
Recommended Products
Online Inquiry